Electrical Integrity Tester

Electrical Integrity Tester

Request Quotation
Electrical Integrity Tester Category
Mini-WDT Sweep Frequency Response Analyzer

Mini-WDT Sweep Frequency Response Analyzer

Mini-WDT sweep frequency response analyzer uses frequency analysis to evaluate whether a transformer has suffered mechanical damage and complies with IEC60076-18.


  • Meet IEC 60076-18 standard

  • Portable and light-weight for easy use

  • Analysis software allows further diagnostics

  • Reproducible results thanks to innovative connection technique

DRT3XXL Series Automated Six-winding Transformer Ohmmeter

DRT3XXL Series Automated Six-winding Transformer Ohmmeter

DRT3XXL series automated six-winding transformer ohmmeter delivers full eight-terminal resistance measurement capability. Widely used in field testing of CT\PT power transformer windings, verifying factory winding resistance test results, etc.


  • Built-in printer

  • Built-in auto-demagnetization

  • DC test current up to 20A(DRT-320L)、40A(DRT-340L)

  • One-time connection principle results in faster setup time eliminating safety risk

  • Automated eight-terminal/six-winding measurement capability

  • Simultaneous winding magnetization for fast and accurate dc winding resistance measurements of high inductive loads

DCR10 Transformer Ohmmeter

DCR10 Transformer Ohmmeter

A portable transformer ohmmeter with an accuracy of ±(reading×0.2%+2) can be used to test transformers, shunt reactors, etc. for low current resistance measurement.


  • DC test current up to 10A

  • 5.6-inch color LED screen

  • Built-in battery(Optional)

  • Wide measurement range (500uΩ ~ 50kΩ) and high accuracy

DCR Series Transformer Ohmmeters

DCR Series Transformer Ohmmeters

  • DC test current up to 20A, 40A, and 50A for different models

  • 7-inch full-color touch display for easy operation and viewing

  • Auto resistance-rate calculation at 5s, 15s, and 30s intervals

  • Ground-wire disconnection alarm function (DCR40/DCR50 only)

MFTS-2A 3-phase Ratio and Winding Resistance Analyzer

MFTS-2A 3-phase Ratio and Winding Resistance Analyzer

The three-phase transformer winding analyzer can perform polarity validation, turns ratio and winding resistance tests with the same one-time lead connection.


  • With TTR and winding resistance tests

  • TTR, range up to 10000,±0.1 % accuracy

  • Save time and protect operators with efficient one-time lead connection for tests

  • Battery powered

TRT-20 3-phase Transformer Turns Ratio (TTR) Tester

TRT-20 3-phase Transformer Turns Ratio (TTR) Tester

The TRT-20 is designed to test all power, instrument (CTs and PTs), and distribution transformers without the need of traditional high voltage excitation.


  • Built in printer

  • Battery powered(Optional)

  • Displays % error vs. name plate value

  • 3-phase test voltage-fast testing of all transformers

STRT-100 True 3-phase Turns Ratio Meter

STRT-100 True 3-phase Turns Ratio Meter

The STRT-100 is designed to test all power, instrument (CTs and PTs), and distribution transformers without the need of traditional high voltage excitation.


  • Portable to carry

  • Built in printer

  • Battery powered (optional)

  • Displays % error vs. name plate value


DRT-340L 40A Automated Six-winding Transformer Ohmmeter

DRT-340L 40A Automated Six-winding Transformer Ohmmeter

DRT-340L 40A Automated Six-Winding Transformer Ohmmeter adopts a one-time connection design, has built-in degaussing function, and three-phase balance analysis to provide a reliable and efficient test solution for the field.


  • Built-in auto-demagnetization

  • Built-in printer

  • DC test current up to 20A or 40A (optional)

DRT-320L 20A Automated Six-winding Transformer Ohmmeter

DRT-320L 20A Automated Six-winding Transformer Ohmmeter

The DRT series of automated six-winding transformer ohmmeters delivers full eight-terminal resistance measurement capability. It's designed to save you time by testing all normal six windings without having to disconnect and reconnect leads during testing.


  • Built-in auto-demagnetization

  • Built-in printer

  • DC test current up to 20A or 40A (optional)

HDRT-310 10A Handheld Three-winding Transformer Ohmmeter

HDRT-310 10A Handheld Three-winding Transformer Ohmmeter

The HDRT-310 is an automatic hand-held battery operated transformer ohmmeter, allows the user to operate the test set while holding it in one hand. It offers 3 test channel up to 10A with a range from 500µΩ to 50kΩ.


  • Battery operated

  • Lightweight – 1.6 kg

  • Handheld design, easy to carry

  • One button test, no need to select current

  • Ability to show three phase winding resistance balance


FAQs about Electrical Integrity Tester

What Parameters Are Included in Electrical Integrity Tests?

Electrical integrity testing evaluates the overall condition of electrical equipment by assessing the health of insulation systems, windings, and electrical circuits. Common test parameters include:


Insulation Assessment

Insulation resistance (IR)

AC and DC withstand voltage tests

Dissipation factor (tan δ)

Winding Evaluation

Winding resistance

Transformer turns ratio (TTR)

Fault Detection

Inter-turn insulation condition

Winding balance and phase-to-phase resistance deviation

Winding deformation analysis

Tap changer contact resistance

Additional Diagnostic Parameters

Excitation current

No-load losses

Ground continuity testing


Together, these measurements provide a comprehensive assessment of equipment condition and reliability.


What Equipment Can Be Tested Using Integrity Testers?

Electrical integrity testers are commonly used for equipment that contains windings, insulation systems, or electrical circuits, including:

  • Power and distribution transformers

  • Dry-type and oil-immersed transformers

  • Electric motors and generators

  • Current transformers (CTs) and voltage transformers (VTs)

  • Reactors and inductive coils

  • Renewable energy converters and associated magnetic components

  • Switchgear components containing electromagnetic assemblies


These tests help verify performance, detect defects, and support preventive maintenance programs.


How Can Testing Extend the Service Life of Transformers?

Routine integrity testing helps identify developing problems before they become major failures.


Benefits include:

  • Early detection of insulation deterioration, moisture ingress, and winding defects

  • Identification of loose connections, tap changer problems, and winding deformation

  • Monitoring of insulation aging trends through historical test data

  • Reduction of overheating, short circuits, and catastrophic failures


By detecting issues at an early stage, maintenance can be planned proactively, helping maximize transformer reliability and service life.


How Often Should Transformer Ratio and Winding Resistance Tests Be Performed?

Testing intervals vary depending on equipment criticality, operating environment, and maintenance requirements.

Ratio and winding resistance tests are commonly performed:

  • Before commissioning new transformers

  • During scheduled preventive maintenance programs

  • After major repairs or tap changer replacement

  • Following short-circuit events, lightning incidents, or abnormal operating conditions

  • Before returning long-idle transformers to service


Asset owners should follow applicable industry standards and maintenance practices when determining test frequency.


What Is a Transformer Turns Ratio (TTR) Test?

A transformer turns ratio (TTR) test compares the actual voltage ratio of transformer windings with the rated ratio specified on the nameplate.

The test is used to identify:

  • Shorted turns

  • Open-circuit windings

  • Incorrect tap changer positions

  • Wiring and connection errors

  • Manufacturing or installation defects


TTR testing is a standard procedure during transformer commissioning, maintenance, and troubleshooting.


Do I Need a Dedicated Transformer Ohmmeter for Winding Resistance Testing?

Yes. Transformer winding resistance measurements are typically performed using a dedicated winding resistance tester rather than a standard multimeter.

Specialized instruments offer:

  • Stable constant-current injection

  • Fast charging of inductive windings

  • Automatic demagnetization functions

  • Rapid discharge protection

  • Higher accuracy for low-resistance measurements


These features improve measurement reliability and significantly reduce testing time, especially for large power transformers.


When Should Winding Resistance Measurements Be Carried Out?

Winding resistance testing is recommended:

  • During factory acceptance and commissioning tests

  • As part of routine preventive maintenance

  • After transformer repairs or winding replacement

  • Following tap changer maintenance

  • After short-circuit, overload, or lightning-related incidents

  • When abnormal temperature rise or unusual operating conditions are detected

  • Before equipment is returned to service after long-term storage


Regular testing helps verify winding integrity and detect developing faults before they affect equipment performance.


Request a Quote for Electrical Testing Equipment
Request a Quote for Electrical Testing Equipment

Please tell us your testing requirements, application scenarios or project details, and our engineers will recommend the solution and quotation that suits you within 24 hours.

Contact Us
Address:
Xianheng Technology Building, No. 101 Xinghuang Alley, Gongshu District, Hangzhou, 310022, China.
Request a Free Quote
Get a Free Quote
Our representative will contact you soon.
* Your Name
* E-mail
* Phone/Whatsapp
Company
Country
* Message/Requirements
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. Part of the tracking is necessary to ensure SEO effectiveness,
By using this site, you agree to our use of cookies. Visit our cookie policy to learn more.
Reject Accept